Industrial Air Make-Up Units for Indoor Air Control

NISCO Co. is a distributor and engineering representative for Direct-Fired Make-Up Air Systems for air temperature control at large industrial plants.

Direct Gas-Fired Heating Systems may be built in a number of configurations. They may be curb mounted as horizontal rooftop systems with down or horizontal discharge or in a vertical configuration for mounting on a pad outside of a building, with air ducted to the interior. They may also be located inside a building, suspended from hangers or mounted on support steel. Various manufacturers can supply any physical configuration required.

Two air flow configurations are available: 100% Fresh Air or Recirculating.

In the 100% Fresh Air arrangement, air is heated as it passes through the unit and supplied to the building space.

In the Recirculating arrangement, a damper is installed to allow a portion of building air to be supplied to the unit and returned to the building. This air is usually introduced downstream of the burner in a pull-through unit. Various percentage settings are available: 80% return / 20% fresh, 50/50, or variable.

It should be noted that demand for recirculating direct gas-fired systems has fallen in recent years. Indoor Air Quality concerns, more stringent regulations passed in recent years, and 2003, new ANSI Standards took effect. Formerly, both recirculating and 100% fresh air units were covered by the same standard. Today, ANSI Z83.4 applies to 100% Fresh Air Units and ANSI Z83.18 applies to Recirculating Units.

Typical components, options and accessories are listed below:

Mounting Curbs:

For installation on building roof. Note – As a service, some manufacturers will also specify mounting requirements for fabrication by others. This allows a contractor to field fabricate a curb for faster installation or allows for third-party fabrication of curbs where the engineer specifies seismic-resistant construction.

Inlet Hoods:

Generally an add-on item. Prevents rain and trash from being drawn into a unit.

Filters:

Filtration may be accomplished using Cleanable Filters mounted in the Inlet Hood or by using a Flat or V-bank Filter Section. For special applications, Bag Filters or HEPA final filters may be specified, but these are not common.

Clogged filter switches and indicators are often supplied to alert maintenance personnel when filters are dirty.

Fans:

Standard units are generally supplied with DWDI (Double Width, Double Inlet) Forward Incline fans. These are competitively priced and offer good performance characteristics. For High Static applications due to building pressurization, long ductwork, filtration, or other reasons, Backward Incline (BI) Fans may be required. Other options that may be specified are Backward Incline Curved (BC) or Airfoil Fans. These are BI fans with higher efficiency and performance, but at higher cost.

Insulation & Lining:

Most manufacturers offer the option of insulation and lining. Standard insulation is generally 1” thick fiberglass or foil face fiberglass board. Linings may be steel or stainless steel to isolate insulation from the air stream. This provides for longer-lasting insulation and eliminates the possibility of contaminating the air stream if insulation breaks down.

Gas-fired pressurization systems each offer good solutions to heating large structures such as warehouses, distribution centers, aircraft hangers, and manufacturing facilities. Situations that require significant ventilation favor pressurization air handlers as do facilities that generate dust, mists, and other contaminants. Cleaner environments with less intensive ventilation needs would do well to go with the infrared radiant heating approach. In very cold climates, it might be beneficial to go with a hybrid solution using radiant heat at the perimeter as the primary heating source and placing pressurization units at the center of the facility for ventilation and for pressurization when doors are open.

Additional information can be found at the NISCO web site http://www.nisco.net/fanblower.html.

Oleg Tchechel
Industrial Air Handling Application Engineer
NISCO Co.
http://www.nisco.net/airhandler.html
http://www.nisco.net/hvac.html

Oleg Tchechel

Oleg Tchechel Developer of Industrial Ventilation Equipment NISCO Fan Co. http://www.nisco.net/custserv.html http://www.nisco.net/inquiry.html

Rate this Article: 0 / 5 stars - 0 vote(s)
Print Email Re-Publish

Add new Comment



Captcha

  • Latest DIY Articles
  • More from Oleg Tchechel

Solar Power Product-Learn How to Build a Solar Power Product

By: N Jamal | 26/12/2009
The greatest thing about solar power is that it has an unlimited potential. Learn how to build a solar power product, easily and save $1000’s on utility bills forever. You just need to know how to make your own renewable energy source and today I am going to tell you exactly how to build your own solar power source.

Solar Powered Products-Learn How to Build Solar Powered Products

By: N Jamal | 26/12/2009
The greatest thing about solar power is that it has an unlimited potential. Learn how to build solar powered products, easily and save $1000’s on utility bills forever. You just need to know how to make your own renewable energy source and today I am going to tell you exactly how to build your own solar power source.

Solar Power Products-Learn How to Build Solar Power Products

By: N Jamal | 26/12/2009
The greatest thing about solar power is that it has an unlimited potential. Learn how to build solar power products, easily and save $1000’s on utility bills forever. You just need to know how to make your own renewable energy source and today I am going to tell you exactly how to build your own solar power source.

How to Convert Solar Energy into Electricity-Learn How to Convert Solar Energy into Electricity

By: N Jamal | 26/12/2009
One of the greatest thing about solar power is that its potential is virtually unlimited. Contrary to the popular belief learning how to convert solar energy into electricity isn’t too technical and you’ll save $1000’s on utility bills. You just need to know how to make your own renewable energy source and today I am going to tell you exactly how to use solar power for producing electricity.

Planet Earth Solar, technology overview, solar countries

By: Drota Kalis | 26/12/2009
Everything alive on Planet Earth is exposed to the Sun. Sun radiation is everywhere, more near the equators less near the poles. Instead of looking downward into coal mines and crude oil drilling sites we better look upward to the Sun.

Pros And Cons Of Solar Energy

By: Drota Kalis | 26/12/2009
Using solar power for home use is very desirable to many people. It allows you to stop relying on the power company and the high bills that go with them, and it allows you to be more friendly to the planet. Below you will find some of the pros and cons of solar power for home use.

How to MAKE PV Solar Panels

By: Drota Kalis | 26/12/2009
The energy we receive everyday from the sun exceeds by far our current daily needs.

DIY Solar Panels

By: Drota Kalis | 26/12/2009
How do you like to build your own DIY solar panels? Having a solar panel system installed at your home can reduce your monthly electric bill by 60%-80%. The interesting part here is you can harness the power of the sun for more or less $200. And there is no need for special skills to create your own DIY solar panels.

Industrial Air Handling Units for Climate Control

By: Oleg Tchechel | 28/04/2009 | Organizational
Makeup air is vitally important to the health and welfare of a building and its occupants. If the proper amount of makeup air is not introduced into a space, consequences can range from exterior doors that are hard to open or close, to buildups of carbon monoxide in the space, to fume hoods that don't actually control the contaminants they were intended to control.

Direct-Fired Gas Industrial Makeup Air Units

By: Oleg Tchechel | 22/04/2009 | Ask an Expert
Gas-Fired Pressurization Units move large quantities of air at low temperature differentials (usually 50° or less), which is a strategy to minimize temperature stratification in the large spaces they are employed to heat. The equipment is typically mounted on the roof of the facility or at grade on elevated supports to ensure that the supply air is delivered high. The high air delivery allows for a longer “throw” of the air, thereby requiring less equipment to cover the required floor area.

Industrial Air Make-Up Units for Indoor Air Control

By: Oleg Tchechel | 14/04/2009 | DIY
It should be noted that demand for recirculating direct gas-fired systems has fallen in recent years. Indoor Air Quality concerns, more stringent regulations passed in recent years, and 2003, new ANSI Standards took effect. Formerly, both recirculating and 100% fresh air units were covered by the same standard. Today, ANSI Z83.4 applies to 100% Fresh Air Units and ANSI Z83.18 applies to Recirculating Units.

NISCO Plastic and Fiberglass Blowers and Fans

By: Oleg Tchechel | 07/04/2009 | Leadership
High-efficiency impellers result in low power consumption, operating costs, and quieter operation. All metal hardware is completely sealed from exposure to corrosion by incapsulating into FRP or plastic; the steel support frame and motor base are powder coated with a corrosion-resistant finish. In addition to being highly resistant to chemical corrosion, PP fans are self-extinguishing and will not support combustion.

Commercial and Industrial Air Handling Units

By: Oleg Tchechel | 06/04/2009 | Customer Service
Return Air Units are widely used for direct fire space heating applications. They can be supplied with a maximum 80% return/20% fresh air, per ANSI standards. Other options include a 50/50 arrangement. “80/20” Units are configured to modulate from the 80% return/20% fresh air to up to 100% outside or fresh air. 50/50 units are generally designed to switch from 50% return / 50% fresh to 100% fresh, with no modulation between.

Air Tight, Zero Leakage Fans and Blowers

By: Oleg Tchechel | 02/04/2009 | Small Business
Some special materials and alloys frequently used in gas tight fans, especially for service in hazardous, abrasive, corrosive and high temperature environments, include: Corten, ASTM A36 Carbon Steel, Hastelloy, Inconel, Stainless Steels of different kinds, Titanium, Monel, Aluminum, Teflon, Rubber LIning. These materials are typical for industrial applications requiring high strength alloys and super alloys too.

Industrial Gas Fired Air Makeup Units

By: Oleg Tchechel | 01/04/2009 | Science
Constant air supply with variable-speed exhaust is recommended where a hot or contaminated environment must be ventilated while maintaining room pressure. Unit may be interlocked to that it only operates with the exhaust system. Variable Air Supply with constant-speed exhaust may be preferred where fume exhausters or fume hoods are used to provide critical ventilation of contaminants from a “clean” environment while make-up air is used to maintain a positive pressure to prevent infiltration

High temperature ventilators and blowers for operating up to 2,200 F

By: Oleg Tchechel | 31/03/2009 | Leadership
NISCO Co. has completely modified its unique line of high temperature fans, ventilators and blowers for industrial applications to 2200 F. This was achived by using extremely high strength stainless steel alloys for the fans impellers, that allow for higher safe speeds at elevated temperatures.

Submit Your Articles Free: Signup
Article Categories




Use of this web site constitutes acceptance of the Terms Of Use and Privacy Policy | User published content is licensed under a Creative Commons License.
Copyright © 2005-2008 Free Articles by ArticlesBase.com, All rights reserved. (0.07, 1, w2)