Unarmored Cables Are The Stronger Choice
Remember Me
forgot your password?

Unarmored Cables Are The Stronger Choice

Why are unarmored cables the stronger choice?

When a conduit or metal clad cable once faces mechanical impact that breaks the consistence of the armor or conduit, the approved mechanical ruggedness at the point of impact is no more given. While TC-ER approved cables with pure polymer construction bounce back like a shock absorber and rebuild the strength of where the impact happened and protect the underlying conductors in a case of another impact. By the requirements of UL the same crush impact test is applied to TC-ER approved and Metal Clad cables. The choice is yours, for us the options are clear: NOBELTM i Cables: tray and crush impact approved cables for exposed runs.

How to find the right cable solution?

Cables rated TC-ER are physically rugged instrumentation and control & power tray cables, using high a construction that they withstand the same crush and impact test as an armored cable. Exposed Run approvals (ER) come into play at type TC tray cables (power and control)  as ITC: instrumentation tray cables and PLTC: power limited tray cables. What to look for as an installer to make the right choice of an approved cable?

Installing cables in horizontal and vertical runs without the usage of conduit requires two approvals:  

  • a) Tray Approval, which is based on surpassing standardized flame test and expressed in TC, ITC, PLTC, CT tray cable approvals
  • b) ER rating -Exposed Run Approval-. ER is a supplemental rating for Cables identifying that they surpass a specified crush-impact test and with that qualify for vertical runs without the usage of mechanical protection like armor or conduit.

 What is an Expose Run (ER) ?

To comply with the ER requirements the UL cable types need to meet certain additional crush and impact test requirements, UL permits the manufacturer to add an  -ER  suffix to the basic Listing printed on the cable, i.e.,  TC-ER ,  ITC-ER  or  PLTC-ER . The  -ER  signifies that the cable is sufficiently rugged to permit its use as exposed wiring.

 Why does NOBEL Service Supply  Promote ER Rated Cables?

NOBEL i Cables with TC-ER approval provide fairly lower total coast installed !

To follow the requirements of the NEC: TC-ER rated cables have to be fixated to a mechanical support every 1.8 meters (6 feet). NOBELTM Tray Cable Systems offer and ideal solution for the mechanical backing where the NOBEL cables can be adhered to with cable ties.

How to find the  ER-Rating  on a Cable?

Here I would casually say: look at the NOBEL Catalog (www.nobelcatalog.com),  but at the end of the day the jacket of ER rated tray cables must be marked (printed) with the letters  TC-ER ,  ITC-ER  or  PLTC-ER  as appropriate for the specific cable. Industry codes and standards require the markings so the electrical inspector at the job site can confirm that the cable meets applicable requirements.

How to ground an  ER-Cable ?

With type TC-ER cables, the NEC requires that an equipment grounding conductor be provided within the cable (NEC Article 336.10(7). However, in 6 AWG and smaller cables any insulated conductor in the cable is permitted to be identified as the equipment grounding conductor at the time of installation. This can be accomplished by stripping the insulation from the entire exposed length, coloring the exposed insulation green, or marking the exposed insulation with green tape or green labels ( NEC Article 250.119(B)).Cable types ITC-ER and PLTC-ER are not required to have an equipment grounding conductor (Articles 725.61(D)(4) and 727.4(6).

Other ER-Requirements

The NEC has several additional requirements that must also be met before ER rated cables can be used in exposed runs. These include:

  • Exposed runs are permitted only in industrial establishments where the conditions of maintenance and supervision ensure that qualified persons service the installation.
  • The exposed run must be between a cable tray and equipment such as a motor.
  • Type ITC cables are limited to 15 m (50 ft) in length between tray and equipment. Type TC and type PLTC cables have no length restrictions.
  • Cables must be supported and protected against physical damage using mechanical protection such as struts, angles or channels.
  • Cables must be secured at least every 1.8 m (6 ft).

 The choice is yours and we from NOBEL Service Supply promote and propose TC-ER approved cable and help our customers to reduce overall electrical installation costs up to 47%.

When costs matter: contact NOBEL Service Supply for TC-ER-Solutions

Dr. Nobel

More than 20 years of technical and business experience

Rate this Article: 0 / 5 stars - 0 vote(s)
Print Email Re-Publish

Add new Comment



Captcha

  • Latest Electronics Articles
  • More from Dr. Nobel

Electronic Gadgets – the choice of wholesalers

By: dhgatezou | 18/12/2009
It is a spontaneous penchant for the people to conserve a bulk of cash. Though there are a numerous of substances contained in retail, the best plan is to avail the substances in mass. This is because using the bulk things you can save a bulk of money. It is better to purchase the things in bulk as the cost of the thing decreases a bulk as the measure increases. Though there are plenty famous types of conserving funds on thing buying, the best method of acting so is with the aid of bulk things.

Amazon Kindle Q&A

By: bookfreefaq | 18/12/2009
I hold a grill in the region of putting books on the amazon kindle? I have about 60 books in my room alone. I be wondering if on the amazon kindle, you could put the serial number of the book on there so you don't have to buy it again. Because I really want one and I don't want to spend hundreds of...

Get A Free Sponge Bob DVD Player!

By: Stephen | 17/12/2009
You have a chance to receive a brand new Free Sponge Bob DVD Player! Keep Reading To Find Out How...

Sony BRAVIA KDL-65W5100 LCD TV - Rich Features for Stunning Pictures!

By: jeffmbs | 17/12/2009
Featuring the MotionFlow 120Hz technology for smooth images, the Sony BRAVIA KDL-65W5100 Flat-panel Television offers astounding HDTV performance. The 1080p screen resolution gets full marks when coupled with Blu-ray disc players that deliver full HD content.

Panasonic TC-P58S1 - Perfect Entry-level Entertainer!

By: jeffmbs | 17/12/2009
The 58-inch Panasonic TC-P58S1 plasma TV is a step-down from the G10 series but offers the best of viewing experience with the detailed images, deep blacks, and remarkable brightness all with lower power consumption.

Sony BDP-S560 – For Enthralling High Definition Experience!

By: jeffmbs | 17/12/2009
The Sony BDP-S560 Blu-ray Disc Player elevates your HD experience with Full HD 1080p video output. It also upscales your standard DVDs to near HD quality via HDMI. This step-up model over the BDP S350 1080p Blu-ray Disc Player from Sony comes with built-in wireless functionality, allowing Wi-Fi protected set-up for a quick and easy connection to WPS enabled wireless routers.

Cables to go – Your online guide to audio/video cables

By: Naval Sharma | 17/12/2009
Although Audio/video cables have always been looked at as merely wires used to connect various media components, but in reality....

Wireless Lighting Control IP & Litigation

By: Bharat Book Bureau | 17/12/2009
Bharatbook.com added a new report on "Wireless Lighting Control IP & Litigation - A WTRS Report" evaluates protection strategies and the impact on the market growth for Wireless Lighting Control technologies.

How to Liquid Tight a Cable Feed Through

By: Dr. Nobel | 23/10/2009 | Electronics
Feeding a cable into an electric box always gives the challenge of how to best protect the valuable interior from the penetration of dust and liquids, which can be harmful to the electrical and electronics components inside. With NOBEL Cord Grips, an ideal solution is found, that combines: sealing liquid tight, providing strain relieve, with ease of installation.

What is Reverse Representation™?

By: Dr. Nobel | 23/07/2009 | Ask an Expert
Reverse Representation is a new concept to focus on satisfying customers needs with world best economical, technical and ecological solutions.

Top 5 Reasons To No More Use Conduit

By: Dr. Nobel | 13/05/2009 | Business
New cable constrictions and methods of “exposed run” are ringing the final bell for the usage of conduit in electrical Installations. Conduit is known as mechanical, chemical and fire protection for wires and cables and used over the last 100 years in many industrial applications. New Cable constructions and installation methods provide the same resistance as a conduit protected wire or cable without the need for a metal conduit or armor.

Unarmored Cables Are The Stronger Choice

By: Dr. Nobel | 20/03/2009 | Electronics
Wiring up a factory or new machine installations does not require steel conduit or metal clad cables to put a mechanically rugged electrical installation in place. With the use of unarmored cables rated ER in combination with cable trays, an installation method is proposed that reduced installation costs up to 47%. To find technical details and a good overview we propose for you to check chapter 1 of the NOBEL Catalog at NOBELcatalog.com

The 3 Most Common Mistakes in Electrical Installations

By: Dr. Nobel | 02/02/2009 | Electronics
In this article we explain methods for cost efficient, secure and fast electrical installations and how we can help to reduce the overall costs and keep committed installation times.

Submit Your Articles Free: Signup
Article Categories




Use of this web site constitutes acceptance of the Terms Of Use and Privacy Policy | User published content is licensed under a Creative Commons License.
Copyright © 2005-2008 Free Articles by ArticlesBase.com, All rights reserved. (0.03, 0, w2)